<?xml version="1.0" encoding="UTF-8"?>
<feed xmlns="http://www.w3.org/2005/Atom" xmlns:dc="http://purl.org/dc/elements/1.1/">
  <title>DSpace Communidade:</title>
  <link rel="alternate" href="http://dspace.uniube.br:8080/jspui/handle/123456789/468" />
  <subtitle />
  <id>http://dspace.uniube.br:8080/jspui/handle/123456789/468</id>
  <updated>2026-03-10T19:33:28Z</updated>
  <dc:date>2026-03-10T19:33:28Z</dc:date>
  <entry>
    <title>SISTEMA DE CONTROLE FUZZY DE COLUNAS DE DESTILAÇÃO DE ETANOL</title>
    <link rel="alternate" href="http://dspace.uniube.br:8080/jspui/handle/123456789/534" />
    <author>
      <name>Pereira Teixeira, Edilberto</name>
    </author>
    <author>
      <name>Zuffi, Fidelis</name>
    </author>
    <id>http://dspace.uniube.br:8080/jspui/handle/123456789/534</id>
    <updated>2019-08-21T12:35:07Z</updated>
    <published>2016-01-01T00:00:00Z</published>
    <summary type="text">Título: SISTEMA DE CONTROLE FUZZY DE COLUNAS DE DESTILAÇÃO DE ETANOL
Autor(es): Pereira Teixeira, Edilberto; Zuffi, Fidelis
Resumo: Apresenta-se, neste trabalho, um sistema para controle fuzzy para colunas de destilação e que tem sido utilizado com sucesso em usinas de produção de etanol, com o objetivo de controle da densidade de saída do produto e do controle da vazão de vinho. O sistema é implantado em um computador que troca mensagens com o controlador lógico programável (CLP), via comunicação OPC. O operador do processo tem disponível a opção de escolher o controle convencional, ou o controle fuzzy, diretamente da tela do sistema supervisório de operação do processo. Caso haja algum problema, o controle do processo retorna para o operador, simultaneamente à ocorrência de alarme específico. O controle da vazão de vinho de entrada e da densidade do etanol são implementados por meio de controladores fuzzy que incluem até cinco variáveis de entrada. Cada variável está associada a três funções de pertinência, que contribuem para a atualização da variável de controle. Desta forma, a base de regras gerada contempla todas as possíveis circunstâncias, atuando de forma repetitiva, com o objetivo de redução do erro de controle. Neste trabalho, são apresentados os detalhes desses controladores.</summary>
    <dc:date>2016-01-01T00:00:00Z</dc:date>
  </entry>
  <entry>
    <title>REMOÇÃO DE ÁCIDO SULFÍDRICO EM COLUNA DE ABSORÇÃO</title>
    <link rel="alternate" href="http://dspace.uniube.br:8080/jspui/handle/123456789/533" />
    <author>
      <name>Gomes Menezes Porto, Fabrício</name>
    </author>
    <author>
      <name>Luiz Begnini, Mauro</name>
    </author>
    <author>
      <name>Delalibera Finzer, José Roberto</name>
    </author>
    <id>http://dspace.uniube.br:8080/jspui/handle/123456789/533</id>
    <updated>2019-08-21T12:35:06Z</updated>
    <published>2016-01-01T00:00:00Z</published>
    <summary type="text">Título: REMOÇÃO DE ÁCIDO SULFÍDRICO EM COLUNA DE ABSORÇÃO
Autor(es): Gomes Menezes Porto, Fabrício; Luiz Begnini, Mauro; Delalibera Finzer, José Roberto
Resumo: Alguns fenômenos físicos, químicos ou eletroquímicos que causam a decomposição de um material, geralmente metálico, podem ser definidos como corrosão. Analisando os meios desfavoráveis e determinando as suas características, vários métodos eficazes podem ser desenvolvidos para evita-la, consistindo numa delas a absorção do agente oxidante. Essa técnica fundamenta-se em reduzir significativamente a concentração do composto. Sendo o ácido sulfídrico uma substância corrosiva, a sua presença excessiva em correntes gasosas intensifica a deterioração dos equipamentos durante o contato. O objetivo deste trabalho foi absorver ácido sulfídrico de biogás. O estudo de absorção foi realizado aplicando uma solução de hidróxido de sódio a 5%. O dispositivo projetado consistiu numa coluna de recheio cilíndrica, portando uma entrada de gás e um distribuidor no fundo, que ainda suporta o recheio, além de uma entrada de líquido e distribuidor no topo. O gás tratado é liberado pelo topo da coluna, e o líquido é descarregado no fundo, contendo ácido sulfídrico absorvido na forma de sais. No projeto, a vazão de biogás foi de 15m³/h com 3% em mol de ácido sulfídrico e a torre foi preenchida com anéis Rasching de 1,5 polegadas. Os cálculos realizados possibilitaram o dimensionamento de uma coluna de absorção com 0,10 m de diâmetro e 3,00 m de altura do recheio, ocorrendo uma perda de pressão de 0,5 cm de coluna de água/m.</summary>
    <dc:date>2016-01-01T00:00:00Z</dc:date>
  </entry>
  <entry>
    <title>ESTIMATIVA DE CONCENTRAÇÃO DE POLUENTES ATMOSFÉRICOS PROVENIENTES DE UM DISTRITO INDUSTRIAL</title>
    <link rel="alternate" href="http://dspace.uniube.br:8080/jspui/handle/123456789/532" />
    <author>
      <name>Antônio Pereira de Lima, Euclides</name>
    </author>
    <author>
      <name>Mohamed Homaied, Soraia</name>
    </author>
    <author>
      <name>Kalil Homaied, Pablo</name>
    </author>
    <id>http://dspace.uniube.br:8080/jspui/handle/123456789/532</id>
    <updated>2019-08-21T12:35:05Z</updated>
    <published>2016-01-01T00:00:00Z</published>
    <summary type="text">Título: ESTIMATIVA DE CONCENTRAÇÃO DE POLUENTES ATMOSFÉRICOS PROVENIENTES DE UM DISTRITO INDUSTRIAL
Autor(es): Antônio Pereira de Lima, Euclides; Mohamed Homaied, Soraia; Kalil Homaied, Pablo
Resumo: A cidade de Uberlândia MG é estratégica para o desenvolvimento de sua região, principalmente devido sua privilegiada localização, seja pelas malhas rodoviárias, ferroviárias ou aeroportuárias, o que proporcionou aumento nas instalações industriais. Associado ao crescimento ocorre também um significativo incremento na geração de poluentes, entre eles destacam-se as emissões atmosféricas. Os poluentes emitidos por fontes pontuais podem ser monitoradas por meio de amostragens isocinéticas, mas quando se trata de qualidade do ar em uma comunidade, torna-se difícil e onerosa a identificação da fonte emissora do mesmo. Uma forma de avaliação da contribuição de determinada fonte sobre a qualidade do ar pode ser com a utilização de modelos matemáticos. Com o uso de um modelo gaussiano de dispersão de poluentes, estimou-se a contribuição dos contaminantes de 48 fontes situadas no Distrito industrial. Os parâmetros estudados foram MP, SO2 e NO2, utilizando dados de amostragens isocinéticas. Os resultados encontrados demonstraram que as concentrações dos poluentes estão abaixo do limite máximo permitido, mas a direção predominante dos ventos favorece que a poluição atinja parte significativa da cidade. O modelo utilizado foi eficiente e de fácil operação, mas quando se trata de várias fontes ao mesmo tempo, deve-se utilizar a programação do visual basic, seguindo a mesma sistemática do modelo AID.</summary>
    <dc:date>2016-01-01T00:00:00Z</dc:date>
  </entry>
  <entry>
    <title>DISPERSÃO DE DIÓXIDO DE TITÂNIO EM FORMULAÇÕES DE TINTAS</title>
    <link rel="alternate" href="http://dspace.uniube.br:8080/jspui/handle/123456789/531" />
    <author>
      <name>Silva Spirlandelli, Gabriela</name>
    </author>
    <author>
      <name>Delalibera Finzer, José Roberto</name>
    </author>
    <author>
      <name>Maikel Fernandes, David</name>
    </author>
    <id>http://dspace.uniube.br:8080/jspui/handle/123456789/531</id>
    <updated>2019-08-21T12:35:03Z</updated>
    <published>2016-01-01T00:00:00Z</published>
    <summary type="text">Título: DISPERSÃO DE DIÓXIDO DE TITÂNIO EM FORMULAÇÕES DE TINTAS
Autor(es): Silva Spirlandelli, Gabriela; Delalibera Finzer, José Roberto; Maikel Fernandes, David
Resumo: O processo de dispersão das partículas consiste em atuar sobre a junção das matérias-primas por forças eletrostáticas. Na homogeneização utilizam-se dispersantes. Este trabalho tem por objetivo verificar a influência de três formulações com diferentes quantidades de dispersante a base de poliacrilato de sódio (AQ 9921)® em emulsão aquosa com cargas e pigmento dióxido de titânio. Relaciona-se a qualidade das formulações com a viscosidade, tempo de homogeneização e poder de recobrimento. Foram realizadas três formulações com 1%, 0,1% e sem dispersante, usando dispersor de bancada do tipo Cowles. Após o tempo de cura, realizou-se análises de pH, consistência, massa específica, poder de cobertura, brilho, aderência, conteúdo de sólidos em porcentagem mássica e viscosidade. O teste que apresentou melhores resultados foi com 0,1% de dispersante, sendo o tempo de dispersão de 40 minutos, viscosidade em copo Ford nº4 de 83 segundos e quantidade de sólidos em suspensão de 46,8%.</summary>
    <dc:date>2016-01-01T00:00:00Z</dc:date>
  </entry>
</feed>

